Units and specifications

Eight units in Building A, drawings, MEP and lease formats. Figures are the stated project parameters.

Typical unit dock court — project visualisation
Project visualisation

Key parameters

125 428m²20 ha · Phases A and B

6 315m²
minimum unit
12m
clear height
8t/m²
floor load

Full specification

62,714 m² is one phase GFA by the project figures; 125,428 m² in total.
ParameterValue
Total GFA125 428 m²
Site20 ha
PhasesA and B · 62 714 m² each
Typical unit6 300–9 500 m²
Clear height12 m
Floor load8 t/m²
Column grid12 × 24 m
Docks1 / 800 m² · level +1.2 m
Temperature+18…+24 °C
Power4.5 MW
Gas1 550 m³/h
Water255 m³/day
Fire protectionESFR 25 · 60 / 158 l/s
HGV parking1 space per 1 000 m²

Building A

Eight units from 6,315 to 9,505 m². One occupier per unit; subdivision is not offered. GBA is gross building area; office amenity is the administrative block.

Unit 1

6 315m²

Gross building area

Warehouse area
4 990 m²
Office amenity
970 m²

Availability on request

Unit 8

9 505m²

Gross building area

Warehouse area
7 850 m²
Office amenity
1 030 m²

Availability on request

Table scrolls horizontally

Building A unit areas, m²
UnitGBA, gross block areaWarehouseOfficeMezzaninePlant
16 3154 99097028075
26 3305 00597028075
38 3706 74097058575
48 3706 7151 03055075
57 1605 810970280100
67 1805 780970280150
79 5007 850970580100
89 5057 8501 03055075

Drawings

Overall plan, units 1 and 8, office amenity, section and mezzanines. Click to open full size.

Building services

Systems as specified. Brands are baseline or equivalents of the same class.

Interior of a completed Griffin warehouse — not this project.
Interior of a completed Griffin warehouse — not this project.
Heating

From an on-site boiler plant built into the building. Buran hot-water boilers; Etra plate heat exchangers; Wilo circulation pumps; Atall / Aquamodule water softening; Wester expansion vessels.

Ventilation and smoke extract

Supply-extract with heat recovery and smoke hatches. AHUs with a rotary heat-recovery wheel, NED / KORF / VTS; Ducted and rooftop supply and extract units; Prado / Fondital radiators; Lamilux / Keraplast rooflights; Smoke extract fans for the office area.

Water and fire protection

Internal and external loops, ESFR 25. Geberit Pluvia outlets with trace heating; ESFR 25 sprinklers (FM Global); External 60 l/s, internal 158 l/s.

Lighting

Even light for racked storage. LED Varton; Anti-glare to the UGR criterion; Uniform illuminance across the warehouse.

Dock equipment

One dock per 800 m² of warehouse area. Alutech / Hörmann automatic doors; Dock shelters and dock levelers; Pits recessed for a tail-lift.

Security

Gated, guarded site 24/7. Automatic fire alarm; Voice alarm, access control, CCTV; Building-services automation.

Lease

Contracts in tenge from 5 years, CPI indexation. Terms on request.

Built-to-suit

Construction to the occupier’s brief. Programme and scope are agreed individually.

What unit sizes are available?

A typical unit is 6,315 to 9,505 m². Building A comprises eight units. Each phase is 62,714 m², 125,428 m² in total.

Is a unit let as a whole?

Yes. One occupier per unit. Subdivision of a unit is not offered in this product.

Is this lease or built-to-suit?

Both. A lease is a typical unit. Built-to-suit means construction to the occupier’s brief. Programme and scope are agreed individually.

When will the first space be ready?

Phase 1 completion — end of Q2 2027.

What utilities are on the plot?

Power 4.5 MW, gas 1,550 m³/h, water 255 m³/day. On-site boiler plant, ESFR 25 fire protection (FM Global).